2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):72. doi: 10.28920/dhm48.2.72. PMID: 29888377PMCID: PMC6173353.

The future of diving research in Norway

Andreas Møllerløkken

Former Associate Professor, Department of Circulation and Medical Imaging, Faculty of Medicine and Health Sciences, NTNU Norwegian University of Science and Technology, NTNU, Trondheim, Norway.
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words

Decompression sickness; Diving research; Editorials; History; Research

 

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Publication Type: Editorial

Full editorial available here.

 


2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):73-78. doi: 10.28920/dhm48.2.73-78. PMID: 29888378. PMCID: PMC6156828.

Audit of practice in Australasian hyperbaric units on the incidence of central nervous system oxygen toxicity

Susannah Sherlock1,2, Mandy Way3, Alexis Tabah2,4

1 Hyperbaric Medicine Unit and Anaesthesia, Royal Brisbane and Women’s Hospital, Herston, Queensland, Australia
2 Faculty of Medicine, The University of Queensland, Brisbane, Queensland
3 QIMR Berghofer, Biostatistics, Herston, Queensland
4 Intensive Care Unit, Redcliffe Hospital, Redcliffe, Queensland

Corresponding author: Susannah Sherlock, Hyperbaric Medicine Unit and Anaesthesia, Royal Brisbane and Women’s Hospital, Butterfield Street, Herston, Queensland 4029, Australia
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words
Central nervous system; Clinical audit; Diving tables; Hyperbaric oxygen therapy; Toxicity

Abstract
(Sherlock S, Way M, Tabah A. Audit of practice in Australian and New Zealand hyperbaric units on the incidence of central nervous sytem oxygen toxicity. Diving and Hyperbaric Medicine. 2018 June;48(2):73–78. doi: 10.28920/dhm48.2.73-78. PMID: 29888378PMCID: PMC6156828.)
Introduction: Central nervous system oxygen toxicity (CNS-OT) is an uncommon complication of hyperbaric oxygen treatment (HBOT). Different facilities have developed local protocols in an attempt to reduce the risk of CNS-OT. This audit was performed to elucidate which protocols might be of benefit in mitigating CNS-OT and to open discussion on adopting a common protocol for Treatment Table 14 (TT14) to enable future multicentre clinical trials.
Methods: Audit of CNS-OT events between units using different compression profiles for TT14, performed at 243 kPa with variable durations of oxygen breathing and ‘air breaks’, to assess whether there is a statistical diference between protocols. Data were collected retrospectively from public and private hyperbaric facilities in Australia and New Zealand between
01 January 2010 and 31 December 2014.
Results: Eight of 15 units approached participated. During the five-year period 5,193 patients received 96,670 treatments. There were a total of 38 seizures in 33 patients when all treatment pressures were examined. In the group of patients treated at 243 kPa there were a total of 26 seizures in 23 patients. The incidence of seizure per treatment was 0.024% (2.4 per 10,000 treatments) at 243 kPa and the risk per patient was 0.45% (4.5 in 1,000 patients). There were no statistically significant differences between the incidences of CNS-OT using different TT14 protocols in this analysis.
Conclusion: HBOT is safe and CNS-OT is uncommon. The risk of CNS-OT per patient at 243 kPa was 1 in 222 (0.45%; range 0−1%) and the overall risk irrespective of treatment table was 0.6% (range 0.31−1.8%). These figures are higher than previously reported as they represent individual patient risk as opposed to risk per treatment. The wide disparity of facility protocols for a 243 kPa table without discernible influence on the incidence of CNS-OT rates should facilitate a national approach to consensus.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Publication Type: Original article

Full article available here.

 


2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):79-83. doi: 10.28920/dhm48.2.79-83. PMID: 29888379. PMCID: PMC6156823.

Rhinologic and oral-maxillofacial complications from scuba diving: a systematic review with recommendations

Devon M Livingstone, Beth Lange

Division of Otolaryngology – Head and Neck Surgery, Department of Surgery; University of Calgary, Calgary, Alberta, Canada

Corresponding author: Devon Livingstone, Division of Otolaryngology – Head and Neck Surgery, Department of Surgery, University of Calgary, 7th floor, 4448 Front Street SE, Calgary, Alberta, Canada, T3M 1M4
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words
Dental; ENT; Rhinolog*; Barotrauma; Treatment; Review article

Abstract

(Livingstone DM, Lange B. Rhinologic and oral-maxillofacial complications from scuba diving: a systematic review with recommendations. Diving and Hyperbaric Medicine. 2018 June;48(2):79–83. doi: 10.28920/dhm48.2.79-83. PMID: 29888379PMCID: PMC6156823.)
Rhinologic and oral maxillofacial complications from scuba diving are common, representing approximately 35% of head and neck pathology related to diving. We performed a systematic and comprehensive literature review on the pathophysiology, diagnosis, and treatment of rhinologic and oral maxillofacial pathology related to diving. This included complications due to sinus barotrauma, barodontalgia, odontocrexis, temporomandibular joint dysfunction, partially dentulous patients, and considerations for patients following major head and neck surgery. Of 113 papers accessed, 32 were included in the final synthesis. We created a succinct summary on each topic that should inform clinical decision making by otolaryngologists, dive medicine specialists and primary care providers when faced with pathology of these anatomic sub-sites.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Publication Type: Review article

Full article available here.

 


 2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):84-95. doi: 10.28920/dhm48.2.84-95. PMID: 29888380. PMCID: PMC6156824.

In-water recompression

David J Doolette, Simon J Mitchell

Department of Anaesthesiology, University of Auckland, Auckland, New Zealand

Corresponding author: Professor Simon J Mitchell, Department of Anaesthesiology, University of Auckland, Private bag 92419, Auckland, New Zealand
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words
Decompression sickness; Decompression illness; First aid; Treatment; Oxygen; Remote locations; Technical diving

Abstract

(Doolette DJ, Mitchell SJ. In-water recompression. Diving and Hyperbaric Medicine. 2018 June;48(2):84–95. doi: 10.28920/dhm48.2.84-95. PMID: 29888380PMCID: PMC6156824.)
Divers suspected of suffering decompression illness (DCI) in locations remote from a recompression chamber are sometimes treated with in-water recompression (IWR). There are no data that establish the benefits of IWR compared to conventional first aid with surface oxygen and transport to the nearest chamber. However, the theoretical benefit of IWR is that it can be initiated with a very short delay to recompression after onset of manifestations of DCI. Retrospective analyses of the effect on outcome of increasing delay generally do not capture this very short delay achievable with IWR. However, in military training and experimental diving, delay to recompression is typically less than two hours and more than 90% of cases have complete resolution of manifestations during the first treatment, often within minutes of recompression. A major risk of IWR is that of an oxygen convulsion resulting in drowning. As a result, typical IWR oxygen-breathing protocols use shallower maximum depths (9 metres’ sea water (msw), 191 kPa) and are shorter (1–3 hours) than standard recompression protocols for the initial treatment of DCI (e.g., US Navy Treatment Tables 5 and 6). There has been no experimentation with initial treatment of DCI at pressures less than 60 feet’ sea water (fsw; 18 msw; 286 kPa; * see footnote) a since the original development of these treatment tables, when no differences in outcomes were seen between maximum pressures of 33 fsw (203 kPa; 10 msw) and 60 fsw or deeper. These data and case series suggest that recompression treatment comprising pressures and durations similar to IWR protocols can be effective. The risk of IWR is not justified for treatment of mild symptoms likely to resolve spontaneously or for divers so functionally compromised that they would not be safe in the water. However, IWR conducted by properly trained and equipped divers may be justified for manifestations that are life or limb threatening where timely recompression is unavailable.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Publication Type: Review article

Full article available here.

 


 2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):96-101. doi: 10.28920/dhm48.2.96-101. PMID: 29888381. PMCID: PMC6156827.

Storage of partly used closed-circuit rebreather carbon dioxide absorbent canisters

Neal W Pollock1,2, Nicholas Gant3, David Harvey4, Peter Mesley5, Jason Hart3, Simon J Mitchell4,6

1Department of Kinesiology, Université Laval, Quebec, Canada
2Service de Médecine Hyperbare, Centre de Médecine de Plongée du Québec, Hôtel-Dieu de Lévis, Levis, Quebec
3Exercise Neurometabolism Laboratory, Department of Exercise Science, University of Auckland, Auckland, New Zealand
4Department of Anaesthesia, Auckland City Hospital, Auckland
5Lust for Rust Diving, Auckland
6Department of Anaesthesiology, University of Auckland, Auckland

Corresponding author: Professor Simon J Mitchell, Department of Anaesthesiology, School of Medicine, University of Auckland, Private Bag 92019, Auckland, New Zealand
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words
Hypercapnia; Technical diving; Soda lime; Respiratory; Equipment

Abstract
(Pollock NW, Gant N, Harvey D, Mesley P, Hart, J, Mitchell SJ. Storage of partly used closed-circuit rebreather carbon dioxide absorbent canisters. Diving and Hyperbaric Medicine. 2018 June;48(2):96–101. doi: 10.28920/dhm48.2.96-101. PMID: 29888381PMCID: PMC6156827.)
Introduction: Diving rebreathers use “scrubber” canisters containing soda lime to remove carbon dioxide (CO2) from the expired gas. Soda lime has a finite ability to absorb CO2. We undertook an experiment to determine whether the manner of storage of a partly used scrubber affected subsequent CO2 absorption.
Methods: An Evolution Plus™ rebreather was mechanically ventilated in a benchtop circuit. Respiratory minute volume was 45 L∙min-1 and CO2 was introduced to the expiratory limb at 2 L∙min-1. The scrubber canister was packed with 2.64 kg of Sofnolime 797™. Scrubbers were run in this circuit for 90 minutes then removed from the rebreather and stored in packed form under one of three conditions: “open” (unsealed) for 28 days (n = 4); vacuum “sealed” in an airtight plastic bag for 28 days (n = 5); or open overnight (n = 5). Following storage the scrubber canisters were placed back in the rebreather and run as above until the PCO2 in the inspired gas exceeded 1 kPa. The total duration of operation to reach this end-point in each storage condition was compared.
Results: The mean run times to reach an inspired CO2 of 1 kPa were 188, 241, and 239 minutes in the open-28-day, the sealed-28-day and the open-overnight storage conditions, respectively.
Conclusion: Rebreather divers should consider placing partially used soda lime scrubber canisters in vacuum-sealed plastic bags if storing them for longer periods than overnight. If a partially used scrubber canister is to be used again the next day then the storage modality is unlikely to influence scrubber efficacy.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Publication Type: Technical report

Full article available here.

 


2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):102-106. doi: 10.28920/dhm48.2.102-106. PMID: 29888382. PMCID: PMC6156829.

Performance of the Oxylog® 1000 portable ventilator in a hyperbaric environment

Lie Sui An1, Loy Shun Ting1, Lee Cheng Chuan2, Kim Soo Joang2, Soh Chai Rick2

1 Department of Anaesthesiology, Singapore General Hospital, Singapore
2 Hyperbaric and Diving Medicine Centre, Singapore General Hospital, Singapore

Corresponding author: Dr Lie Sui An, Department of Anaesthesiology, Singapore General Hospital, Outram Road, Singapore 169608
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words
Equipment; Performance; Pressure; Hyperbaric research; Safety

Abstract
(Lie SA, Loy ST, Lee CC, Kim SJ, Soh CR. Performance of the Oxylog® 1000 portable ventilator in a hyperbaric environment. Diving and Hyperbaric Medicine. 2018 June;48(2):102–106. doi: 10.28920/dhm48.2.102-106. PMID: 29888382PMCID: PMC6156829.)
Introduction: The management of mechanically ventilated patients in the hyperbaric environment requires knowledge of how the physical properties of gases change under pressure and how this affects the operation of the ventilator. The primary objective of this study was to test the performance of the Dräger Oxylog 1000® ventilator in a hyperbaric environment.
Methods: Each of two ventilators was connected to a mechanical test lung system with an in-built pressure gauge. We used a Wright’s respirometer to measure the tidal volumes. The same ventilator settings were tested under varying environmental pressures from ambient (101.3 kPa) to 18 meters’ sea water (284 kPa) in a multiplace hyperbaric chamber.
Results: A decrease was found in tidal volume, decrease in airway pressure and increase in respiratory rate delivered by the Dräger Oxylog 1000 portable ventilator with increasing pressures to 284 kPa.
Discussion: These findings can be explained by the operating principles of the Oxylog 1000, which is a time-controlled, constant-volume ventilator that functions as a flow chopper. Even between the two Oxylog 1000 ventilators tested there were different absolute changes in tidal volume, airway pressures and respiratory rates at various depths. Hence, the trend of changes in these variables is probably more important than absolute values.
Conclusion: In summary, understanding the trend of changes in ventilator variables will allow clinicians to make appropriate corrections in ventilator settings and carefully monitor adequacy of ventilation to prevent adverse ventilator-associated events. The Dräger Oxylog 1000 portable ventilator is an adequate back-up ventilator for use with straight-forward, ventilator-dependent patients undergoing hyperbaric treatment.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Publication Type: Technical report

Full article available here.

 


2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):107-109. doi: 10.28920/dhm48.2.107-109. PMID: 29888383. PMCID: PMC6156826.

Repeated hyperbaric exposure and glass ampoule safety

Soon Yee Teoh1, Venkat Narasimham Vangaveti2

1 Diving and Hyperbaric Medicine Unit, Townsville Hospital and Health Service, Townsville, Queensland, Australia
2 College of Medicine and Dentistry, James Cook University, Townsville

Corresponding author: Dr Soon Y Teoh, Diving and Hyperbaric Medicine Unit, Townsville, Hospital and Health Service, 100 Angus Smith Drive, Douglas, Queensland, Australia 4814
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words
Pharmacology; Equipment; Safety; Risk assessment; Pressure

Abstract
(Teoh SY, Vangaveti VN. Repeated hyperbaric exposure and glass ampoule safety. Diving and Hyperbaric Medicine. 2018 June;48(2):107–109. doi: 10.28920/dhm48.2.107-109. PMID: 29888383PMCID: PMC6156826.)
Introduction: It has been our institution’s policy to not place glass medication ampoules inside our hyperbaric chamber for fear of rupture. There is only a small and conflicting amount of data as to whether lass ampoules are safe for use under hyperbaric conditions.
Objectives: The primary objective of this study was to test the safety and usability of glass medication ampoules inside a hyperbaric chamber.
Methods: Repetitive, rapidly staged compressions and decompressions were performed on multiple different glass medication ampoules inside the medical lock of a medical hyperbaric chamber. Medication ampoules of varying sizes (1 ml to 10 ml) of medications that may be required in a hyperbaric emergency were assessed. The ampoules were rapidly compressed
100 times to pressures of 142 kPa, 183 kPa, 300 kPa, 405 kPa and 507 kPa. They were then dropped from a height of 30 cm while compressed at 507 kPa and then half the ampoules were opened while pressurized at 507 kPa.
Results: No ampoules were broken during compression or decompression. No ampoules broke when dropped from 30 cm onto the chamber floor. All ampoules opened at a pressure of 507 kPa functioned normally. No lids/ampoules shattered upon opening.
Conclusion: This study suggests that glass medication ampoules appear to be safe for use inside a medical hyperbaric chamber at routine treatment pressures.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Publication Type: Technical report

Full article available here.

 


2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):110-111. doi: 10.28920/dhm48.2.110-111. PMID: 29888384. PMCID: PMC6156822.

Problems with an intrathecal pump in a paraplegic scuba diver

Brahim Hacene1, Nathalie Draulans1, Tom Theys2

1 Department of Physical and Rehabilitation Medicine, University Hospitals Leuven, Belgium
2 Department of Neurosurgery, University Hospitals Leuven

Corresponding author: Dr Brahim Hacene, Department of Physical and Rehabilitation Medicine, University Hospitals, Leuven, Belgium
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words
Recreational diving; Medications; Implantable devices; Pressure; Spinal cord injury; Case reports

Abstract

(Hacene B, Draulans N, Theys T. Problems with an intrathecal pump in a paraplegic scuba diver. Diving and Hyperbaric Medicine. 2018 June;48(2):110–111. doi: 10.28920/dhm48.2.110-111. PMID: 29888384PMCID: PMC6156822.)
Scuba diving with an intrathecal baclofen pump is encouraged for people with spinal cord injury who are suffering from spasticity. However, the diving depth is limited to 10 metres in this context. Proper physician and patient education in this respect is mandatory since non-compliance can lead to an irreversible loss of drug reservoir capacity due to collapse of the bottom shield. We report such an incident in a paraplegic diver diving to depths down to 30 metres’ water.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in printed and other forms.

Publication Type: Case report

Full article available here.

 


2018 June;48(2)

Diving Hyperb Med. 2018 June;48(2):112-113. doi: 10.28920/dhm48.2.112-113. PMID: 29888385. PMCID: PMC6156825.

Acute ophthalmic artery occlusion in decompression illness with underlying anterior cerebral artery A1 segment hypoplasia

Ahmad Razif Omar, Mohtar Ibrahim, Adil Hussein

Ophthalmology Department, School of Medical Science, University Sains Malaysia, Kelantan, Malaysia

Corresponding author: Ahmad R Omar, Ophthalmology Department, School of Medical Science, University Sains Malaysia, 16150-Kubang Kerian, Kelantan, Malaysia
This email address is being protected from spambots. You need JavaScript enabled to view it.

Key words
Decompression sickness; Cerebral arterial gas embolism; Blindness, sudden; Cerebral blood flow; Ophthalmology; Risk factors; Case reports

Abstract

(Omar AR, Ibrahim M, Hussein A. Acute ophthalmic artery occlusion in decompression illness with underlying anterior cerebral artery A1 segment hypoplasia. Diving and Hyperbaric Medicine. 2018 June;48(2):112–113. doi: 10.28920/dhm48.2.112-113. PMID: 29888385PMCID: PMC6156825.)
A diver presented with total loss of vision in the left eye and right hemiparesis following a routine no-stop scuba dive to 20 metres’ depth. A diagnosis of decompression illness (DCI) with acute ophthalmic artery air embolism and left carotid artery insult causing acute anterior circulatory ischaemia was made. He underwent seven hyperbaric treatments leading to a full recovery. Magnetic resonance angiography revealed an underlying left anterior cerebral artery A1 segment hypoplasia. Making a prompt diagnosis and early hyperbaric oxygen treatment are crucial to halt further tissue damage from ischaemia in central nervous system DCI. In this case, the finding of a left A1 anterior cerebral artery segment hypoplasia variant may have increased the severity of DCI due to deficient collateral circulation.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Publication Type: Case report

Full article available here.

 


⇐ BACK 

Diving and Hyperbaric Medicine

is indexed on

MEDLINE, Science Citation Index Expanded (SciSearch®) and Embase/Scopus and complies with the International Committee of Medical Journal Editors (ICMJE) Recommendation for the Conduct, Report, Editing and Publication of Scholarly Work in Medical Journals. Articles from 2017 are deposited in PubMed Central.