The full article is currently under embargo for 12 months and will be made available on our website and PMC after this period. If you would like to access the article before it becomes publicly available, you can purchase it for personal use directly on our website. Alternatively, you may join SPUMS or EUBS to gain access to the entire issue.

Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation

Silvio Zerbi1, Luigi Tarsia2, Vincenzo Benenati3, Dario Nicosia4, Gerardo Bosco5, Matteo Paganini2

1 Department of Anesthesiology and Intensive Care, ASST Sette Laghi, Varese, Italy
2 Independent Researcher, Padova, Italy
3 Anesthesiology, Intensive Care and Hyperbaric Medicine, Policlinico Universitario “P. Giaccone”, Palermo, Italy
4 UOC Centrale Operativa 118, ARNAS Civico, Palermo, Italy
5 Department of Medicine and Aging Sciences, University “G. D’Annunzio” Chieti – Pescara, Italy

Corresponding author: Dr Silvio Zerbi, Department of Anesthesiology and Intensive Care. ASST Sette Laghi, Viale Borri, 57 – 21100 Varese (VA), Italy
ORCiD: 0009-0004-4280-432X
This email address is being protected from spambots. You need JavaScript enabled to view it.

Keywords
Catheter ablation; Electrocardiography; Electrophysiology; Diving medicine; Hyperbaric oxygen; Hyperbaric medicine; Implantable loop recorder

Abstract

(Zerbi S, Tarsia L, Benenati V, Nicosia D, Bosco G, Paganini M. Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation. Diving and Hyperbaric Medicine. 2026 30 June;56(2):203−207. doi: 10.28920/dhm56.2.203-207. PMID: 42290583.)
Pulmonary vein isolation (PVI) is an established rhythm-control therapy for atrial fibrillation (AF), yet the electrophysiological response of post-PVI individuals exposed to hyperbaric environments remains undocumented. Similarly, the in-vivo performance of implantable loop recorders (ILRs) and external patch-based electrocardiographic (ECG) devices under increased ambient pressure has never been reported. We describe the first hyperbaric electrophysiology assessment in a post-PVI diver undergoing both underwater immersion and dry hyperbaric exposure with dual-modality cardiac rhythm monitoring. A 46-year-old experienced diver with successful PVI underwent: a scuba dive to 42 m in a warm water pool, monitored with a marinised 12-lead ECG Holter system; and a stepwise hyperbaric chamber compression to 284 kPa 
(2.8 atmospheres absolute) in ambient air, with single-lead surface ECG recordings obtained at static pressure plateaus. In both cases, the subject was monitored as well by his ILR. No AF recurrence or other dysrhythmias were detected during either exposure, with stable heart rate trends. The ILR maintained full functional integrity after both the 42 m dive and the 284 kPa chamber compression. The external ECG patch yielded interpretable tracings during static phases. Telemetry failed due to electromagnetic shielding by the steel chamber walls. This case suggests that carefully selected post-PVI individuals may tolerate controlled underwater and hyperbaric exposure without rhythm destabilisation. Both implantable and external monitoring devices preserved operational integrity under moderate hyperbaric conditions, providing a foundation for the emerging field of hyperbaric electrophysiology monitoring and informing fitness-to-dive assessment in post-ablation patients.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

South Pacific Underwater Medicine Society 


EUBS

European Underwater Baromedical Society

About our Publishers... 

Access to the journal can be obtained by becoming a member of either society, European Underwater Medicine Society (EUBS) or South Pacific Underwater Medicine Society (SPUMS). 

Click their linked logos to find out more.

 

Diving and Hyperbaric Medicine

is indexed on

MEDLINE, Science Citation Index Expanded (SciSearch®) and Embase/Scopus and complies with the International Committee of Medical Journal Editors (ICMJE) Recommendation for the Conduct, Report, Editing and Publication of Scholarly Work in Medical Journals. Articles from 2017 are deposited in PubMed Central.

Diving and Hyperbaric Medicine Journal
Department of Anaesthesiology
University of Auckland
Private Bag 92019, Auckland 1142
New Zealand
E: info@dhmjournal.com

 

E-ISSN 2209-1491
ABN 29 299 823 713

 

Get in touch